HFCs
Genetron Performax® LT (R-407F)
A non-ozone depleting replacement for R-22 in various refrigeration applications.
A non-ozone depleting replacement for R-22 in various refrigeration applications.
General Information
- Contains
- HFC-32, HFC-125, HFC-134a
- Brand
- Genetron®
- Glide
- Moderate
- Refrigerant Class
- Blend
- Application
- Commercial Refrigeration
- Typical Lubricant
- POE
- Refrigerant Type
- HFC
- ASHRAE Number
- R-407F
- Substitutes
- HCFC-22
- Chemical Name
- Difluoromethane, Pentafluoroethane, Tetrafluoroethane
Physical Properties
- Molecular Weight
- 82.1 lbm/lbmol
- Specific Heat of Liquid
- 0.39 Btu/lb at 86 °F
- Saturated Liquid Density
- 68.3 lb/ft3 at 86 °F
- Critical Pressure
- 689.6 psia
- Specific Heat of Vapor
- 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
Temperature
- Critical Temperature
- 180.8 °F ASTM D-1321
- Boiling Point/Range
- -50.9 °F at 1 Atm
Safety & Environment
- Flammable Range
- None, %vol. in air Based on ASHRAE Standard 34 with Match Ignition
Standards & Approvals
- ASHRAE Safety Classification
- A1
General Information
- Contains
- HFC-32, HFC-125, HFC-134a
- Brand
- Genetron®
- Glide
- Moderate
- Refrigerant Class
- Blend
- Application
- Commercial Refrigeration
- Typical Lubricant
- POE
- Refrigerant Type
- HFC
- ASHRAE Number
- R-407F
- Substitutes
- HCFC-22
- Chemical Name
- Difluoromethane, Pentafluoroethane, Tetrafluoroethane
Physical Properties
- Molecular Weight
- 82.1 lbm/lbmol
- Specific Heat of Liquid
- 0.39 Btu/lb at 86 °F
- Saturated Liquid Density
- 68.3 lb/ft3 at 86 °F
- Critical Pressure
- 689.6 psia
- Specific Heat of Vapor
- 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
Temperature
- Critical Temperature
- 180.8 °F ASTM D-1321
- Boiling Point/Range
- -50.9 °F at 1 Atm
Safety & Environment
- Flammable Range
- None, %vol. in air Based on ASHRAE Standard 34 with Match Ignition
Standards & Approvals
- ASHRAE Safety Classification
- A1
- Contains : HFC-32, HFC-125, HFC-134a
- Brand : Genetron®
- Glide : Moderate
- Refrigerant Class : Blend
- Application : Commercial Refrigeration
- Typical Lubricant : POE
- Refrigerant Type : HFC
- ASHRAE Number : R-407F
- Substitutes : HCFC-22
- Chemical Name : Difluoromethane, Pentafluoroethane, Tetrafluoroethane
- Molecular Weight : 82.1 lbm/lbmol
- Specific Heat of Liquid : 0.39 Btu/lb at 86 °F
- Saturated Liquid Density : 68.3 lb/ft3 at 86 °F
- Critical Pressure : 689.6 psia
- Specific Heat of Vapor : 0.2 Btu/lb at 86 °F and 1 Atm, at Cp
- Critical Temperature : 180.8 °F ASTM D-1321
- Boiling Point/Range : -50.9 °F at 1 Atm
- Flammable Range : None, %vol. in air Based on ASHRAE Standard 34 with Match Ignition
- ASHRAE Safety Classification : A1
Image
SKU
Description
10329614
Genetron Performax® LT 11.3kg/25lb Cyl
10329611
Genetron Performax® LT ISO Tank
10329613
Genetron Performax® LT 11.3kg/25lb Cyl CA
10630444
Genetron Performax® LT 1600lb/726kg Ton
10294524
Genetron Performax® LT 52.2kg/115lb Cyl
10640214
Genetron Performax® LT 115lb/52.2kg CA SQ